When a furnace maintenance is performed a combustion analysis should be performed to identify any problems that couldn't be found by a visual inspection. You want to know what the Carbon monoxide level your furnace is producing as well as the oxygen/CO2 levels and stack temperate. The analyzer will also give you a calculated efficiency rating with the information the analyzer receives. You should have >100ppm of Carbon monoxide output during normal operation of your gas furnace. When you have higher numbers or CO numbers increasing during operation their is a problem with the furnace the technician should then find the cause of. This is just a brief explanation I'm trying to get across to those who get their furnace maintained and to those who don't! Check to see if anyone in the company has a NCI certification for carbon monoxide/combustion analysis.
Furnaces and thermostats are not mix-and-match appliances. Using the wrong type of thermostat with a furnace will cause operating problems and can be dangerous. Although thermostats look similar, they are designed very differently. There are numerous types of heating systems and thermostat systems and they need to be coordinated for safe and proper operation. There are three types of thermostat systems used today: millivoltage, low voltage, and line voltage.​
When a furnace maintenance is performed a combustion analysis should be performed to identify any problems that couldn't be found by a visual inspection. You want to know what the Carbon monoxide level your furnace is producing as well as the oxygen/CO2 levels and stack temperate. The analyzer will also give you a calculated efficiency rating with the information the analyzer receives. You should have >100ppm of Carbon monoxide output during normal operation of your gas furnace. When you have higher numbers or CO numbers increasing during operation their is a problem with the furnace the technician should then find the cause of. This is just a brief explanation I'm trying to get across to those who get their furnace maintained and to those who don't! Check to see if anyone in the company has a NCI certification for carbon monoxide/combustion analysis.

Furnace Service Company


There’s a common misconception that you can save money by shutting the vents (supply registers) in rooms that aren’t being utilized. Resist the urge to close too many, as doing so can actually increase the pressure in your furnace, making it work harder to heat your home. This can lead to failed blower motors, mold or mildew in your ductwork, damage to the compressor, a cracked heat exchanger, and other problems. What Does a Furnace Tune-Up Include?
Regarding your post, Every technician performs a maintenance differently. Today's modern furnaces really don't require as much maintenance as older style systems did. For instance: Older furnaces had drive belts, pulleys and motors with oil ports.Today's blowers are direct drive no belts, no pulleys, sealed bearing motors no oiling required. All of the new modern technology cuts the maintenance time in half if not more. Today's equipment has multiple safety's in place so that in case of a failure the system will shut down. non serviceable control boards or (Brains) monitor system functions. Unlike oil systems, the maintenance on a gas system can possibly be completed in less than half the time. I'd say 20 to 30 minutes is about right unless a service issue arises. In the 30 minute time span, the doors can be removed, system components can be visually inspected, the flame can be inspected and co test can be performed for spillage and vacuum of the combustion area can be performed if needed. The air filter should be checked and the humidifier can be activated. Remember that probing into a perfectly functioning system can be detrimental to its lifespan. My advice is change you air filter, keep the area around the equipment free of dust and try not to store in close proximity to the heating plant. Be sure you have an updated quality carbon monoxide detector in your home. Regarding the crack in your heat ex-changer, If the heat ex-changer had a crack in it, the system it should have been shut down right then and there. Be aware that Carbon monoxide may be entering your living space due to that crack. Have a knowledgeable company come back and do a CO test in your home at the supply vents and use a scope to check your heat ex-changer for cracks. I hope this helps you. Bottom line, you have to trust the company that you are using. If you feel uncertain about their capabilities, then more than likely, you instinct is correct. Good Luck to you.. Happy Holidays
AAA Heating and Cooling has been the leader in residential and commercial furnace installation, heating services and air conditioning repair for thousands of clients throughout Portland, Beaverton, Hillsboro, Lake Oswego and the surrounding areas for over half a century. As a family-owned Portland, OR business, we offer a variety of services, including the installation of home heating and air conditioning systems, AC and furnace service and repair, duct cleaning as well as a variety of commercial heating and cooling solutions. 